Compare Products
Hide
VS
Offices, hotels, retail stores, factories, and schools
Modelos
Serie
Características destacadas
Hardware Specifications |
RG-S2915-48GT4MS-L |
RG-S2915-24GT4MS-L |
RG-S2915-24GT4MS-P-L |
RG-S2915-10GT2MS-P-L |
Interface Specifications |
||||
Fixed Service Ports |
48 × 10/100/1000Base-T Ethernet ports with auto-negotiation, 4 × 2.5GE/1GE SFP ports |
24 × 10/100/1000Base-T Ethernet ports with auto-negotiation, 4 × 2.5GE/1GE SFP ports |
24 × 10/100/1000Base-T Ethernet ports with auto-negotiation, 4 × 2.5G/1GE SFP ports |
10 × 10/100/1000Base-T Ethernet ports with auto-negotiation, 2 × 2.5GE/1GE SFP ports |
Power modules |
1 fixed power module |
1 fixed power module |
1 fixed power module |
1 fixed power module |
Fans modules |
2 fixed fans |
0 |
2 fixed fans |
1 fixed fans |
Fixed management ports |
1 × RJ45 Console, 1 × USB port |
1 × RJ45 Console, 1 × USB port |
1 × RJ45 Console, 1 × USB port |
1 × RJ45 Console, 1 × USB port |
System Specifications |
||||
Packet forwarding rate |
87 Mpps |
51 Mpps |
51 Mpps |
22.5 Mpps |
System Switching capacity |
116Gbps |
68Gbps |
68Gbps |
30Gbps |
MAC Table Capacity |
16,000 |
16,000 |
16,000 |
16,000 |
ARP table |
512 |
|||
Routing Table Size (IPv4/IPv6) |
64 |
|||
ACL entries |
500 |
|||
Dimensions and Weight |
||||
Dimensions (W x D x H) |
440 mm × 220 mm × 43.5 mm (17.32 in × 8.66 in × 1.71 in), 1 RU |
440 mm × 220 mm × 43.5 mm (17.32 in × 8.66 in × 1.71 in), 1 RU |
440 mm × 292 mm × 43.6 mm (17.32 in × 11.50 in × 1.72 in), 1 RU |
297 mm × 170 mm × 44.5 mm (11.69 in × 6.69 in × 1.75 in), 1 RU |
Weight |
2.8 kg (6.17 lbs) |
2.5 kg (5.51 lbs) |
2.8 kg (6.17 lbs) |
2.5 kg (5.51 lbs) |
CPU and Storage |
||||
CPU |
Built-in CPU, single-core processor, with the clock speed of 1.2 GHz |
|||
Storage |
SDRAM: 512 MB Flash Memory: 64 MB |
|||
Power and Consumption |
||||
Maximum power consumption |
< 30 W |
< 15.6 W |
< 33 W (non-PoE) < 403 W (PoE full load) |
< 16 W (non-PoE) < 141 W (PoE full load) |
Rated input voltage |
100 V AC to 240 V AC, 50 Hz to 60 Hz |
100 V AC to 240 V AC, 50 Hz to 60 Hz |
100 V AC to 240 V AC, 50 Hz to 60 Hz |
100 V AC to 240 V AC, 50 Hz to 60 Hz |
Maximum input voltage |
90 V AC to 264 V AC, 50 Hz to 60 Hz |
90 V AC to 264 V AC, 50 Hz to 60 Hz |
90 V AC to 264 V AC, 50 Hz to 60 Hz |
90 V AC to 264 V AC, 50 Hz to 60 Hz |
Environment and Reliability |
||||
MTBF |
>200K |
>200K |
>200K |
>200K |
Operating Temperature |
0°C to 45°C (32°F to 113°F) |
|||
Storage Temperature |
-40°C to +70°C (-40°F to +158°F) |
|||
Operating Humidity |
10% to 90% RH (non-condensing) |
|||
Storage Humidity |
5% to 95% RH (non-condensing) |
|||
Operating noise |
≤ 37 dB |
Fanless |
≤ 39 dB |
≤ 37 dB |
Interface surge protection |
Power port: 6 kV/2 kV Telecom port: 10 kV |
Power port: 6 kV/2 kV Telecom port: 10 kV |
Power port: 6 kV/2 kV Telecom port: 10 kV |
Power port: 6 kV/2 kV Telecom port: 10 kV |
Feature |
Description |
|
Ethernet switching |
Jumbo frame (maximum length: 9216 bytes) |
|
802.3az EEE |
||
IEEE 802.1Q (4,094 VLANs) |
||
Voice VLAN |
||
Port based VLAN |
||
Basic QinQ Selective QinQ |
||
STP (IEEE 802.1.d), RSTP (IEEE 802.1w), MSTP (IEEE 802.1s) |
||
ERPS (G.8032) |
||
LLDP/LLDP-MED |
||
LACP (IEEE 802.3ad) |
||
IP service |
ARP |
|
DHCP client, DHCP relay, and DHCP server |
||
DHCP snooping |
||
DNS |
||
IP routing |
Static routing |
|
RIP, RIPng |
||
OSPFv2 |
||
ACL and QoS |
Standard IP ACLs Extended IP ACLs Extended MAC ACLs Expert-level ACLs ACL 80 IPv6 ACL |
|
ACL redirection |
||
Port traffic rate limiting |
||
802.1p, DSCP, IP precedence traffic prioritization (IEEE 802.1p) for real-time classification |
||
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ |
||
Congestion avoidance: tail drop |
||
Eight priority queues per interface |
||
Security |
RADIUS and TACAS+ |
|
Port-based and MAC-based 802.1x authentication |
||
Web authentication |
||
HTTPS |
||
SSHv1, SSHv2 |
||
IGMP V1,V2 snooping |
||
IP Source Guard |
||
CPP and NFPP |
||
Reliability |
RLDP |
|
Hot swapping of power modules and cables |
||
Temperature Monitoring Temperature Alarm Overtemperature Protection |
||
NMS and maintenance |
RSPAN |
|
sFlow |
||
NTP |
||
TFTP client |
||
SNMP v1/v2c/v3 |
||
CLI (telnet/console), syslog/debug, Web, MACC public cloud |
||
CWMP (TR-069) standard protocol |
||
gRPC |
||
PoE |
IEEE 802.3af and 802.3at Uninterruptible power supply upon hot start Port priority |
Model |
Description |
RG-S2915-48GT4MS-L |
48 × 10/100/1000Base-T copper ports with auto-negotiation, 4 × 1GE/2.5GE SFP ports, fixed single AC power supply |
RG-S2915-24GT4MS-L |
24 × 10/100/1000Base-T copper ports with auto-negotiation, 4 × 1GE/2.5GE SFP ports, fixed single AC power supply |
RG-S2915-24GT4MS-P-L |
24 × 10/100/1000Base-T copper ports with auto-negotiation, 4 × 1GE/2.5GE SFP ports, fixed single AC power supply, PoE/PoE+ power supply, 370 W PoE power supply |
RG-S2915-10GT2MS-P-L |
10 × 10/100/1000Base-T copper ports with auto-negotiation, 2 × 1GE/2.5GE SFP ports, fixed single AC power supply, PoE/PoE+ power supply, 125 W PoE power supply |
2.5G-SFP-LX03-SM1310-BIDI-I |
SFP 2.5G BIDI transceiver-TX1310/RX1550, 3 km, LC |
2.5G-SFP-LX03-SM1550-BIDI-I |
SFP 2.5G BIDI transceiver-TX1550/RX1310, 3 km, LC |
MINI-GBIC-SX-MM850 |
1000BASE-SX, SFP transceiver, SM (850 nm, 500 m, LC). |
MINI-GBIC-LX-SM1310 |
1000BASE-LX, SFP transceiver, SM (1310 nm, 10 km, LC) |
MINI-GBIC-LH40-SM1310 |
1000BASE-LH, SFP transceiver, SM (1310 nm, 40 km, LC) |
MINI-GBIC-ZX80-SM1550 |
1000BASE-ZX80, SFP transceiver, SM (1550 nm, 80 km, LC) |
GE-SFP-LX20-SM1310-BIDI |
SFP BIDI Transceiver-TX1310/RX1550, 20 km, LC |
GE-SFP-LX20-SM1550-BIDI |
SFP BIDI Transceiver-TX1550/RX1310, 20 km, LC |
GE-SFP-LH40-SM1310-BIDI |
SFP BIDI Transceiver-TX1310/RX1550, 40 km, LC |
GE-SFP-LH40-SM1550-BIDI |
SFP BIDI Transceiver-TX1550/RX1310, 40 km, LC |
Mini-GBIC-GT |
1000BASE-TX, SFP transceiver (100 m) |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Contáctenos
How can we help you?
Your opinions and feelings are crucial for our improvement.
Fill in the survey