Compare Products
Hide
VS
RDMA-capable high-density 25GE/100GE access switch for data center networks with low latency and no packet drop
four service slots, 25GE/40GE/100GE line cards
RG-S6510-48VS8CQNumber of IPv4/IPv6 host routing entries: 128K/64K
RG-S6510-32CQ32×100G ports
Hardware Specifications
System Specifications |
RG-S6510-48VS8CQ |
RG-S6510-32CQ |
Ports |
48 x 25GE SFP28 ports and 8 × 100GE QSFP28 ports |
32 x 100GE QSFP28 ports |
Expansion Module Slots |
Two power module slots, supporting 1+1 redundancy Four fan module slots, supporting 3+1 redundancy |
Two power module slots, supporting 1+1 redundancy Five fan module slots, supporting 4+1 redundancy |
Management Port |
One management port, one console port, and one USB port, compliant with the USB2.0 standard |
|
Switching Capacity |
4.0Tbps |
6.4 Tbps |
Packet Forwarding Rate |
2000 Mpps |
2030 Mpps |
802.1Q VLAN |
4094 |
|
Dimensions and Weight |
||
Dimensions (W × D × H) |
442 mm x 387 mm x 44 mm (17.40 in. x 15.24 in. x 1.73 in., 1 RU) |
442 mm x 560 mm x 44 mm (17.40 in. x 22.05 in. x 1.73 in., 1 RU) |
Weight |
About 8.2 kg (18.08 lbs, including two power supply modules and four fan modules) |
About 11.43 kg (25.20 lbs, including two power supply modules and five fan modules) |
Power Supply and Consumption |
||
AC |
● Rated voltage: 110 V AC/220 V AC ● Rated voltage range: 100 V AC to 240 V AC (50 Hz to 60 Hz) ● Max voltage range: 90 V AC to 264 V AC (47 Hz to 63 Hz) ● Rated input current range: 3.5 A to 7.2 A |
|
High-voltage DC |
Input voltage range: 192 V DC to 288 V DC Input current: 3.6 A |
|
Low-voltage DC |
● Input voltage range: –36 V DC to –72 V DC ● Rated input voltage: –48 V DC ● Rated input current: 23 A |
N/A |
Maximum Power Consumption |
● Max: 300 W ● Typical: 172 W ● Static: 98 W |
● Max: 450 W ● Typical: 270 W ● Static: 150 W |
Environment and Reliability |
||
Operating Temperature |
0°C to 45°C (32°F to 113°F) |
0°C to 40°C (32ºF to 104ºF) |
Storage temperature |
-40 °C to 70 °C (-40 °F to 158 °F) |
|
Operating Humidity |
10%RH to 90% RH (Non-condensing) |
|
Storage humidity |
5% to 95% RH (non-condensing) |
|
Working altitude |
Operating altitude: up to 5000 m (16,404.20 ft.) |
Software Specifications
Software Specifications |
RG-S6510-48VS8CQ |
RG-S6510-32CQ |
L2 Protocols |
IEEE802.3ad (Link Aggregation Control Protocol), IEEE802.1p, IEEE802.1Q, IEEE802.1D (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP Snooping, MLD Snooping, Jumbo Frame (9 KB), IEEE802.1ad (QinQ and Selective QinQ), GVRP |
|
L3 Protocols (IPv4) |
BGP4, OSPFv2, RIPv1, RIPv2, MBGP, LPM Routing, Policy-based Routing (PBR), Route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP, IGMP v1/v2/v3, DVMRP, PIM-SSM/SM/DM, MSDP, Any-RP |
|
IPv6 Basic Protocols |
Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS |
|
IPv6 Features |
Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+, MLDv1/v2, PIM-SMv6, manual tunnel, automatic tunnel, IPv4 over IPv6 tunnel, and ISATAP tunnel |
|
Multicast |
IGMPv1, v2, v3、IGMP Host Behavior、Member Query and Response、Querier Election、IGMP Proxy、Multicast Static Routing、MSDP、PIM-DM、PIM-SM、PIM-SSM、Enabling PIM on Layer-3 Subinterface、PIM-SMv6、MLD v1 and v2、MLD Proxy、Enabling PIMv6 on Layer-3 Subinterface |
|
ACL |
Standard IP-based ACL、Extended MAC/IP-based ACL、Expert-level ACL、ACL 80、IPv6 ACL、ACL Logging、ACL Counter (Ingress and egress counters are supported in interface or global configuration modes)、ACL Re-marking、Global ACL、ACL-based Redirection、Displaying ACL Resources、Processing First Packet of TCP Handshake When Binding the ACL to Restrict SIP、Matching Against 5-Tuple of Pass-by VXLAN Inner IP Packets、The expert-level ACL supports matching the IP flag and DSCP fields of VXLAN inner packets、Ingress/Egress ACLs |
|
When the same ACL is applied to different physical interfaces or SVIs, resources can be multiplexed |
N/A |
|
Data Center Features |
VXLAN routing and VXLAN bridging IPv6 VXLAN over IPv4 and EVPN VXLAN PFC, ECN, and RDMA M-LAG *RoCE over VxLAN OpenFlow 1.3 |
|
Visualization |
gRPC sFLOW sampling INT |
|
QoS |
Mapping of IEEE 802.1p, DSCP, and ToS priorities |
|
Virtualization |
Virtual Switching Unit |
|
Buffer Management |
Buffer status monitoring and management, and identification of burst traffic |
|
HA Design |
GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules |
|
Security Features |
Network Foundation Protection Policy (NFPP), CPP, DDoS attack defense, illegitimate data packet detection, data encryption, source IP spoofing prevention, IP scanning prevention, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, uRPF, broadcast packet suppression, DHCP Snooping, ARP spoofing prevention, ARP check, and hierarchical user management |
|
Management Mode |
SNMP v1/v2c/v3, Netconf, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP clock, Syslog, SPAN/RSPAN/ERSPAN, Telemetry, ZTP, Python, fan and power alarm, and temperature alarm |
|
Other Protocols |
DHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP relay, ARP Proxy, and Syslog |
Safety and Regulatory Compliance
Specification |
RG-S6510-48VS8CQ |
RG-S6510-32CQ |
Safety |
● IEC 62368-1 ● EN 62368-1 ● NM EN 62368-1 ● NM CEI 62368-1 ● EN IEC 62368-1 ● BS EN IEC 62368-1 ● UL 62368-1 ● CSA C22.2#62368-1 ● GB 4943.1 |
● IEC 62368-1 ● EN 62368-1 ● EN IEC 62368-1 ● UL 62368-1 ● CAS C22.2#62368-1 ● GB 4943.1 |
Electromagnetic Compatibility (EMC) |
● EN 55032 ● EN 55035 ● EN IEC 61000-3-2 ● EN IEC 61000-3-3 ● EN 61000-3-3 ● EN 300 386 ● ETSI EN 300 386 ● NM EN 55035 ● NM EN CEI61000-3-2 ● NM EN 61000-3-3 ● CNS 13438 ● ICES-003 Issue 7 ● ANSI C63.4-2014 ● FCC CFR Title 47, Part 15, Subpart B ● ANSI C63.4-2014 ● VCCI-CLSPR 32 ● GB/T 9254.1 |
● EN 55032 ● EN 55035 ● EN 61000-3-2 ● EN 61000-3-3 ● EN IEC 61000-3-3 ● EN IEC 61000-3-2 ● EN 300 386 ● ETSI EN 300 386 ● CES-003 Issue 7 ● ANSI C63.4-2014 ● FCC CFR Title 47, Part 15,Subpart B ● VCCI-CISPR 32 ● GB/T 9254.1 |
Environment |
● 2011/65/EU EN 50581 ● 2012/19/EU EN 50419 ● (EC) No.1907/2006 ● GB/T 26572 |
● 2011/65/EU EN 50581 ● 2012/19/EU EN 50419 ● (EC) No.1907/2006 ● GB/T 26572 |
*For more country-specific regulatory information and approvals, contact your local sales agency.
The configuration procedure for the RG-S6510 series switches is as follows:
Product Model |
Description |
RG-S6510-48VS8CQ |
48 × 25GE ports and 8 × 100GE ports. |
RG-S6510-32CQ |
Provides 32 × 100G ports. |
Product Model |
Description |
RG-PA550I-F |
550 W power supply module (AC and 240 V HVDC) |
RG-PD800I-F |
800 W power supply module (48 V LVDC), applicable only to RG-S6510-48VS8CQ |
M6510-FAN-F |
Fan module of RG-S6510-48VS8CQ, supporting 3+1 redundancy, hot swapping, and front-to-rear ventilation design. |
M1HFAN I-F |
Fan module of RG-S6510-32CQ, supporting 4+1 redundancy, hot swapping, and front-to-rear ventilation design. |
Product Model |
Description |
100G-QSFP-SR-MM850 |
100G SR module, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over MMF |
100G-QSFP-LR4-SM1310 |
100G LR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF |
100G-QSFP-iLR4-SM1310 |
100G iLR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF |
100G-QSFP-ER4-SM1310 |
100G ER4 module, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.59 ft.) over SMF |
100G-AOC-10M |
100G QSFP28 AOC cable, 10 m (32.81 ft.) |
100G-AOC-5M |
100G QSFP28 AOC cable, 5 m (16.40 ft.) |
Product Model |
Description |
40G-QSFP-SR-MM850 |
40G SR module, QSFP+ form factor, MPO, 150 m (492.13 ft.) over MMF |
40G-QSFP-LR4-SM1310 |
40G LR4 module, QSFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF |
40G-QSFP-LSR-MM850 |
40G LSR module, QSFP+ form factor, MPO, 400 m (1,312.34 ft.) over MMF |
40G-QSFP-iLR4-SM1310 |
40G iLR4 module, QSFP+ form factor, Duplex LC, 2 km (6,561.68 ft.) over SMF |
40G-QSFP-LX4-SM1310 |
40G LX4 module, QSFP+ form factor, Duplex LC connector, 150 m (492.13 ft.) over OM3/OM4 MMF, or 2 km (6,561.68 ft.) over SMF |
40G-AOC-30M |
40G QSFP+ AOC cable, 30 m (98.43 ft.) |
40G-AOC-5M |
40G QSFP+ AOC cable, 5 m (16.40 ft.) |
Product Model |
Description |
VG-SFP-AOC5M |
25G SFP28 AOC cable, 5 m (16.40 ft.) |
VG-SFP-LR-SM1310 |
25G LR module, SFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF |
VG-SFP-SR-MM850 |
25G SR module, SFP28 form factor, Duplex LC, 850 nm, 100 m (328.08 ft.) over MMF |
Product Model |
Description |
XG-LR-SM1310 |
10G LR module, SFP+ form factor, Duplex LC, 10 km ((32,808.40 ft.) over SMF |
XG-SR-MM850 |
10G SR module, SFP+ form factor, Duplex LC, 300 m (984.25 ft.) over MMF |
XG-SFP-AOC1M |
10G SFP+ AOC cable, 1 m (3.28 ft.) |
XG-SFP-AOC3M |
10G SFP+ AOC cable, 3 m (9.84 ft.) |
XG-SFP-AOC5M |
10G SFP+ AOC cable, 5 m (16.40 ft.) |
XG-SFP-SR-MM850 |
10G SR module, SFP+ form factor, Duplex LC, 300 m (984.25 ft.) over MMF |
XG-SFP-LR-SM1310 |
10G LR module, SFP+ form factor, Duplex LC, 10 km ((32,808.40 ft.) over SMF |
XG-SFP-ER-SM1550 |
10G ER module, SFP+ form factor, Duplex LC, 40 km (131,233.60 ft.) over SMF |
XG-SFP-ZR-SM1550 |
10G ZR module, SFP+ form factor, Duplex LC, 80 km (262,467.19 ft.) over SMF |
Product Model |
Description |
GE-SFP-LH40-SM1310-BIDI |
1G LH module, SFP form factor, BIDI LC, 40 km (131,233.60 ft.) over SMF |
GE-SFP-LX20-SM1310-BIDI |
1G LX module, SFP form factor, BIDI LC, 20 km (65,616.80 ft.) over SMF |
GE-SFP-LX20-SM1550-BIDI |
1G LX module, SFP form factor, BIDI LC, 20 km (65,616.80 ft.) over SMF |
MINI-GBIC-LH40-SM1310 |
1G LH module, SFP form factor, Duplex LC, 40 km (131,233.60 ft.) over SMF |
MINI-GBIC-LX-SM1310 |
1G LX module, SFP form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF |
MINI-GBIC-SX-MM850 |
1G SR module, SFP form factor, Duplex LC, 550 m (1,804.46 ft.) over MMF |
MINI-GBIC-ZX80-SM1550 |
1G ZX module, SFP form factor, Duplex LC, 80 km (262,467.19 ft.) over SMF |
Product Model |
Description |
Mini-GBIC-GT(F) |
1G SFP copper module, SFP form factor, RJ45, 100 m (328.08 ft.) over Cat 5e/6/6a |
Mini-GBIC-GT |
1G SFP copper module, SFP form factor, RJ45, 100 m (328.08 ft.) over Cat 5e/6/6a |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Contáctenos
How can we help you?
Your opinions and feelings are crucial for our improvement.
Fill in the survey