Can be deployed in data centers, metropolis area networks, campus networks, or integrated scenarios of data centers and campus networks.
Modelos
Serie
Características destacadas
Two flash chips for storing boot software achieve hardware-level boot redundancy, avoiding switch boot failures due to a flash chip fault.
1+1 hot standby ensures nonstop switch services.
Four hot-swappable power supplies realize failover within seconds and service continuity during power replacement, ensuring link reliability.
Hareware Specifications |
S7805C |
S7808C |
S7810C |
RG-S7808C-V2 |
Interface Specifications |
||||
Power module |
2 |
2 |
4 |
4 |
Supervisor module slot |
2 |
2 |
2 |
2 |
Line card slot |
3 |
6 |
8 |
6 |
Switch fabric module slot |
Built-in |
2 (integrated with supervisor modules) |
4 (2 are integrated with supervisor modules) |
2 (integrated with supervisor modules) |
System Specifications |
||||
Packet forwarding rate |
4,500 Mpps |
9,000 Mpps |
12,000 Mpps |
|
System switching capacity |
6 Tbps |
12 Tbps |
16 Tbps |
|
MAC address |
● Number of global MAC addresses EB card: 64,000 DA card: 96,000 (default) and 288,000 (max.) FA card: 80,000 FB card: 96,000 ● Number of static MAC addresses EB card: 4,000 DA card: 10,000 FA card: 4,000 ● FB card: 40,000 |
|||
ARP table |
EB card: 10,000 (default and recommended) DA card: underlay: 75,000; overlay: 0 (default and recommended) FA card: underlay: 30,000; overlay: 0 FB card: underlay: 50,000; overlay: 0 (default and recommended) |
|||
Number of IPv4 unicast routes |
EB card: 12,000 (default and recommended, shared with IPv6 routes) DA card: 12,000 (default and recommended, shared with IPv6 routes) FA card: 12,000 (default and recommended, shared with IPv6 routes) FB card: 134,000 (default and recommended, shared with IPv6 routes) |
|||
Number of IPv4 multicast routes |
EB card: 8,000 DA card: 16,000 FA card: 8,000 FB card: 16,000 |
|||
Number of IPv6 unicast routes |
EB card: 6,000 (shared with IPv4 routes) DA card: 6,000 (shared with IPv4 routes) FA card: 6,000 (shared with IPv4 routes) FB card: 50,000 (shared with IPv4 routes) |
|||
Number of IPv6 multicast routes |
EB card: 4,000 DA card: 8,000 FA card: 4,000 FB card: 8,000 |
|||
Number of ACEs |
● Ingress EB card: 3,500 DA card: 8,000 FA card: 5,000 FB card: 4,500 ● Egress EB card: 1,000 DA card: 1,000 FA card: 1,000 ● FB card: 2,000 |
|||
Number of VSU members |
2 |
2 |
2 |
2 |
Dimensions and Weight |
||||
Dimensions (W x D x H) |
442 mm x 451 mm x 175 mm (17.40 in. x 17.76 in. x 6.89 in., 4 RU) |
442 mm x 465mm x 441.7 mm (17.40 in. x 18.31 in. x 17.39 in., 10 RU) |
442.5 mm x 560 mm x 442 mm (17.42 in. x 22.05 in. x 17.40 in., 10 RU) |
442 mm x 465mm x 441.7 mm (17.40 in. x 18.31 in. x 17.39 in., 10 RU) |
Weight (empty chassis and fan modules) |
32.35 kg (71.32 lbs) |
35.6 kg (78.48 lbs) |
43.6 kg (96.12 lbs) |
35.6 kg (78.48 lbs) |
CPU and Storage |
||||
CPU |
● Supervisor module M7805C-CM/M7805C-CM II: 1.5 GHz quad-core processor ● Service module EA/EB card: 1.0 GHz quad-core processor DA/F card: 1.5 GHz quad-core processor |
● Supervisor module M7800C-CM: 1.0 GHz quad-core processor M7808C-CM II: 1.5 GHz quad-core processor ● Service module EA/EB card: 1.0 GHz quad-core processor DA/F card: 1.5 GHz quad-core processor |
● Supervisor module M7808C-CM II: 1.5 GHz quad-core processor ● Service module EB card: 1.0 GHz quad-core processor DA/F card: 1.5 GHz quad-core processor ● Switch fabric module M7810C-FE-D I/M7810C-FE-F I: 1.5 GHz quad-core processor |
● Supervisor module M7808C-CM II: 1.5 GHz quad-core processor ● Service module EA/EB card: 1.0 GHz quad-core processor ● DA/F card: 1.5 GHz quad-core processor |
Storage |
Flash memory M7805C-CM/M7805C-CM II: 1 GB EA card: 512 MB EB card: 512 MB DA/F card: 8 GB SDRAM M7805C-CM/M7805C-CM II: DDRIII 4 GB EA card: DDR3 1 GB EB card: DDRIII 1 GB DA card: DDR4 1 GB F card: DDR4 2 GB |
Flash memory Supervisor module: M7800C-CM/M7808C-CM II: 8 GB Service module: EA card: 512 MB EB card: 512 MB DA/F card: 8 GB SDRAM Supervisor module: M7800C-CM: DDR3 4 GB M7808C-CM II: DDR4 4 GB Service module: EB card: DDR3 1 GB DA card: DDR4 1 GB F card: DDR4 2 GB |
Flash memory Supervisor module: M7810C-CM/M7810C-CM-F: 8 GB Service module: EB card: 512 MB DA/F card: 8 GB Switch fabric module: M7810C-FE-D I: 8 GB M7810C-FE-F I: 8 GB SDRAM Supervisor module: M7810C-CM/M7810C-CM-F: DDR4 4 GB Service module: EB card: DDR3 1 GB DA card: DDR4 1 GB F card: DDR4 2 GB Switch fabric module: M7810C-FE-D I card: DDR4 1 GB M7810C-FE-F I: DDR4 2 GB |
Flash memory Supervisor module: M7808C-CM II: 8 GB Service module: EA card: 512 MB EB card: 512 MB DA/F card: 8 GB SDRAM Supervisor module: M7808C-CM II: DDR4 4 GB Service module: EB card: DDR3 1 GB DA card: DDR4 1 GB F card: DDR4 2 GB |
Power and Consumption |
||||
Maximum power consumption |
Chassis RG-S7805C: < 80 W Supervisor module: M7805C-CM II: < 21 W Service module: M7800C-24SFP/12GT4XS-EB: < 85 W M7800C-36GT12SFP4XS-EB: < 80 W M7800C-48GT4XS-EB: < 70 W M7800C-48SFP4XS-EB: < 101 W M7800C-24GT24SFP4XS-EB: < 88 W M7800C-32XS4QXS-DA: < 210 W M7800C-24XT4QXS-DA: < 245 W M7800C-48GT-FA: < 75 W M7800C-48SFP-FA: < 95 W M7800C-48XS-FB: < 160 W M7800C-4CQ-FB: < 120 W M7800C-8CQ-FB: < 130 W |
Chassis RG-S7808C: < 176 W Supervisor module: M7808C-CM II: < 50 W Service module: M7800C-24SFP/12GT4XS-EB: < 85 W M7800C-36GT12SFP4XS-EB: < 80 W M7800C-48GT4XS-EB: < 70 W M7800C-48SFP4XS-EB: < 101 W M7800C-24GT24SFP4XS-EB: < 88 W M7800C-32XS4QXS-DA: < 210 W M7800C-24XT4QXS-DA: < 245 W M7800C-48GT-FA: < 75 W M7800C-48SFP-FA: < 95 W M7800C-48XS-FB: < 160 W M7800C-4CQ-FB: < 120 W M7800C-8CQ-FB: < 130 W |
Chassis RG-S7810C: < 432 W Supervisor module: M7810C-CM: < 50 W M7810C-CM-F: < 110 W Service module: M7800C-24SFP/12GT4XS-EB: < 85 W M7800C-36GT12SFP4XS-EB: < 80 W M7800C-48GT4XS-EB: < 70 W M7800C-48SFP4XS-EB: < 101 W M7800C-24GT24SFP4XS-EB: < 88 W M7800C-32XS4QXS-DA: < 210 W M7800C-24XT4QXS-DA: < 245 W M7800C-48GT-FA: < 75 W M7800C-48SFP-FA: < 95 W M7800C-48XS-FB: < 160 W M7800C-4CQ-FB: < 120 W M7800C-8CQ-FB: < 130 W Switch fabric module: M7810C-FE-D I: < 50 W M7810C-FE-F I: < 105 W |
Chassis RG-S7808C-V2: < 176 W Supervisor module: M7808C-CM II: < 50 W Service module: M7800C-24SFP/12GT4XS-EB: < 85 W M7800C-36GT12SFP4XS-EB: < 80 W M7800C-48GT4XS-EB: < 70 W M7800C-48SFP4XS-EB: < 101 W M7800C-24GT24SFP4XS-EB: < 88 W M7800C-32XS4QXS-DA: < 210 W M7800C-24XT4QXS-DA: < 245 W M7800C-48GT-FA: < 75 W M7800C-48SFP-FA: < 95 W M7800C-48XS-FB: < 160 W M7800C-4CQ-FB: < 120 W M7800C-8CQ-FB: < 130 W |
Maximum output power |
● RG-PA300I-F: 300 W ● RG-PA460I-F: 460 W |
● RG-PA600I-F: 600 W ● RG-PA1600I-F: 90 V to 180 V: 12,00 W 180 V to 264 V: 1,600 W ● RG-PD600I-F: 600 W ● RG-PA800IF: 800 W |
● RG-PA600I: 600 W ● RG-PA1600I: 90 V to 180 V: 1,200 W 180 V to 264 V: 1,600 W ● RG-PD600I: 600 W ● RG-PD1600I: 1,400 W |
● RG-PA600I-F: 600 W ● RG-PA1600I-F: 90 V to 180 V: 12,00 W 180 V to 264 V: 1,600 W ● RG-PD600I: 600 W |
Environment and Reliability |
||||
MTBF |
> 200,000 hours |
|||
Primary Airflow |
● Supervisor module Right-to-left airflow ● Service module Right-to-rear airflow ● System power module Built-in fan modules drawing air outward Front-to-rear airflow |
● Supervisor module /Service module Right-to-rear airflow ● System power module Front-to-rear airflow |
● Line card Side-to-rear airflow ● Supervisor module/FE Front-to-rear airflow |
● Supervisor module /Service module Right-to-rear airflow ● System power module Front-to-rear airflow |
Operating temperature |
0°C to 50°C (32°F to 122°F) |
|||
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
|||
Operating humidity |
10% to 90% RH (non-condensing) |
|||
Storage humidity |
5% to 95% RH (non-condensing) |
|||
Operating altitude |
–500 m to +5,000 m (–1640.42 ft. to +16404.20 ft.) |
|||
Operating noise |
55.9 dB at the temperature of 35°C (95°F) 73.4 dB at the temperature of 50°C (122°F) |
|||
Interface surge protection |
All electrical ports support 4 kV surge protection in common mode or 1 kV surge protection in differential mode. |
Power port: 6 kV Telecom port: 4 kV (MGMT port) |
Software Specifications
RG-S7800C Series |
|
Feature |
Description |
Ethernet switching |
Jumbo frame (maximum length: 9,216 bytes) |
802.3az EEE |
|
Maximum number of VLANs that can be created: 4,094 |
|
Voice VLAN |
|
Super-VLAN and private VLAN |
|
MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment |
|
GVRP |
|
Basic QinQ and selective QinQ |
|
STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) |
|
ERPS (G.8032) |
|
LLDP/LLDP-MED |
|
IP service |
Static and dynamic ARP |
DHCP client |
|
DHCP relay |
|
DHCP server |
|
DHCP snooping |
|
DNS |
|
DHCPv6 client, DHCPv6 relay, and DHCPv6 snooping |
|
Neighbor Discovery (ND) and ND snooping |
|
Manual tunnel, automatic tunnel, and ISATAP tunnel for IPv6 |
|
GRE tunnel |
|
IP routing |
Static routing |
RIP and RIPng |
|
OSPFv2 and OSPFv3 |
|
GR |
|
IPv4/IPv6 IS-IS |
|
BGP4 and BGP4+ |
|
EVPN |
|
IPv4/IPv6 VRF |
|
Policy-based routing (PBR) |
|
IPv4 and IPv6 ECMP |
|
Multicast |
IGMP v1/v2/v3 |
IGMP snooping v1/v2/v3 |
|
IGMP proxy |
|
IGMP fast leave |
|
PIM-DM, PIM-SM, and PIM-SSM |
|
PIM-SSM for IPv4 and IPv6 |
|
MSDP to achieve inter-domain multicast |
|
MLDv1 and MLDv2 |
|
Multicast static routing |
|
MLD v1/v2 snooping |
|
PIM-SMv6 |
|
Multicast source IP address check Multicast source port check |
|
MPLS |
MPLS IPv6 |
MPLS L3VPN |
|
MPLS 6VPE |
|
MPLS MIB (RFC 1273, RFC 4265, and RFC 4382) |
|
ACL and QoS |
Standard IP ACLs (hardware ACLs based on IP addresses) |
Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers) |
|
Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type) |
|
Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range) |
|
ACL80 and IPv6 ACL |
|
Applying ACLs globally (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range) |
|
ACL redirection |
|
Port traffic identification |
|
Port-based rate limiting |
|
802.1p |
|
Traffic classification based on 802.1p priorities, DSCP priorities, and IP precedences |
|
CAR |
|
Congestion management: SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ |
|
Congestion avoidance: tail drop, RED, and WRED |
|
Eight queues on each port |
|
Security |
AAA |
RADIUS authorization and accounting |
|
TACACS+ |
|
Portal authentication, RADIUS, and TACACS+ login authentication |
|
IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication |
|
Web authentication |
|
Hypertext Transfer Protocol Secure (HTTPS) |
|
SSHv1 and SSHv2 |
|
Global IP-MAC binding |
|
ICMP |
|
Port security |
|
IP source guard |
|
DAI |
|
SAVI |
|
ARP spoofing prevention |
|
CPU Protect Policy (CPP) and NFPP |
|
Various attack defense functions, including NFPP and ARP anti-attack |
|
uRPF Login authentication and password security Unknown multicast packets are not sent to the CPU, and unknown unicast packets can be suppressed. |
|
Reliability |
Rapid Ethernet Uplink Protection (REUP) |
Rapid Link Detection Protocol (RLDP), Layer 2 link connectivity detection, unidirectional link detection, and VLAN-based loop control |
|
Data Link Detection Protocol (DLDP) |
|
IPv4 VRRP v2/v3 and IPv6 VRRP |
|
VRRP for the super-VLAN |
|
BFD |
|
1+1 redundancy for supervisor modules and fan modules, and N+M redundancy for power modules |
|
Hot swapping of components |
|
Hot patch and online installation of patches |
|
GR for OSPF/IS-IS/BGP |
|
BFD for VRRP/OSPF/BGP4/ISIS/ISISv6/static routing |
|
Device virtualization |
VSU |
NMS and maintenance |
SPAN, RSPAN, and ERSPAN |
sFlow |
|
NTP |
|
SNTP |
|
FTP, TFTP, and Xmodem |
|
SNMP v1/v2c/v3 |
|
RMON (1, 2, 3, 9) |
|
NETCONF |
|
CWMP |
|
gRPC |
|
OpenFlow Special 1.3 Flow table analysis defined by all protocols Transmission of specified packets to the controller Configuring the controller's IP address and port Notifying port status changes to the controller |
|
Web-based NMS |
|
Console/Telnet/SSH2.0 CLI configuration Fault alarms and auto-recovery System operation logging |
|
VXLAN |
Layer 2 and Layer 3 VXLAN gateways |
Note: The item marked with the asterisk (*) will be available in the future.
Model |
Description |
S7805C |
RG-S7805C switch, which can accommodate three line cards and two supervisor modules |
S7808C |
RG-S7808C switch, which can accommodate six line cards and two supervisor modules |
S7808C-V2 |
RG-S7808C-V2 switch, which can accommodate six line cards and two supervisor modules (only M7808C-CM II supported) |
S7810C |
RG-S7810C switch, which can accommodate eight service cards, two supervisor modules, and two switch fabric modules |
M7805C-CM |
S7805C high-performance 1st-generation supervisor module |
M7805C-CM II |
S7805C high-performance 2nd-generation supervisor module |
M7800C-CM |
S7808C high-performance 1st-generation supervisor module |
M7808C-CM II |
S7808C high-performance 2nd-generation supervisor module |
M7810C-CM |
S7810C high-performance 1st-generation supervisor module |
M7810C-CM-F |
S7810C high-performance 2nd-generation supervisor module |
Model |
Description |
RG-PA300I-F |
S7805C power module (AC, 300 W, 10 A) |
RG-PA460I-F |
S7805C power module (available for redundancy, AC, 460 W, 10 A) |
RG-PA600I-F |
S7808C power module (available for redundancy, AC, 600 W, 10 A) |
RG-PA1600I-F |
S7808C power module (available for redundancy, AC, 1600 W, 16 A) |
RG-PA1600I-PL |
Universal PoE power module (available for redundancy, AC, 1600 W, 16 A) |
RG-PA3000I-PL |
Universal PoE power module (available for redundancy, AC, 3000 W, 16 A) |
RG-PD600I-F |
S7808C power module (available for redundancy, DC, 600 W, –48 V) |
RG-PA600I |
S7810C power module (available for redundancy, AC, 600 W, 10 A) |
RG-PD600I |
S7810C power module (available for redundancy, DC, 600 W, 20 A) |
RG-PA1600I |
S7810C power module (available for redundancy, AC, 1600 W, 16 A) |
RG-PD1600I |
S7810C power module (available for redundancy, DC, 1400 W, 50 A) |
M08-FAN |
S7808C fan: Each M08-FAN tray consists of two fan modules and one fan monitoring card. It blows air to the outside for convection. This is a default configuration for the switches. |
M7800C-48DP |
External power supply card of the RG-S7808C-V2, 48 power output ports per card, and a maximum of 100 W power per port |
Model |
Description |
M7810C-FE-D I |
RG-S7810C switch fabric module I |
M7810C-FE-F I |
RG-S7810C 2nd-generation switch fabric module |
Model |
Description |
M7800C-32XS-XA |
32 x 10GE optical ports (SFP+ and LC) |
M7800C-24GT8SFP8XS-XA |
24 x GE electrical ports (RJ45) + 8 x GE optical ports (SFP, LC) + 8 x 10GE optical ports (SFP+ and LC) |
M7800C-48GT4XS-XA |
48 x GE electrical ports (RJ45) + 4 x 10GE optical ports (SFP+ and LC) |
M7800C-48SFP4XS-XA |
48 x GE optical ports (SFP, LC) + 4 x 10GE optical ports (SFP+ and LC) |
M7800C-52XS-XB |
52 x 10GE optical ports (SFP+ and LC) |
M7800C-12CQ-XB |
12-port 100G/40G optical port (QSFP+ and MPO/LC) |
M7800C-48XS-FB |
48 x 10GE optical ports (SFP+ and LC) |
M7800C-8CQ-FB |
8 x 100G Ethernet optical ports (QSFP28 and LC) |
M7800C-48GT-FA |
48 x GE electrical ports (RJ45) |
M7800C-48SFP-FA |
48 x GE optical ports (SFP+ and LC) |
M7800C-16SFP8XS-EA |
16 x GE optical ports (SFP and LC) + 8 x 10GE optical ports (SFP+ and LC) |
M7800C-24SFP/12GT4XS-EA |
24 x GE optical ports (SFP and LC) + 12 x GE electrical combo ports (RJ45) + 4 x 10GE optical ports (SFP+ and LC) |
M7800C-24GT24SFP4XS-EA |
24 x GE electrical ports (RJ45) + 24 x GE optical ports (SFP and LC) + 4 x 10GE optical ports (SFP+ and LC) |
M7800C-36GT12SFP4XS-EA |
36 x GE electrical ports (RJ45) + 12 x GE optical ports (SFP and LC) + 4 x 10GE optical ports (SFP+ and LC) |
M7800C-48SFP4XS-EA |
48 x GE optical ports (SFP and LC) + 4 x 10GE optical ports (SFP+ and LC) |
M7800C-48GT4XS-EA |
48 x GE electrical ports (RJ45) + 4 x 10GE optical ports (SFP+ and LC) |
M7800C-32XS4QS-DA |
32 x 10GE optical ports (SFP+ and LC) + 4 x 40G Ethernet optical ports (QSFP+ and MPO) |
M7800C-24XT4QXS-DA |
24 x 10GE electrical ports (RJ45) + 4 x 40G Ethernet optical ports (QSFP+ and MPO) |
M7800C-24GT24SFP4XS-EB |
24 × GE electrical ports (RJ45) + 24 x GE optical ports (SFP and LC) + 4 x 10GE optical ports (SFP+ and LC) |
M7800C-24SFP/12GT4XS-EB |
24 x GE optical ports (SFP and LC) + 12 x GE electrical combo ports (RJ45) + 4 x 10GE optical ports (SFP+ and LC) |
M7800C-48GT4XS-EB |
48 x GE electrical ports (RJ45) + 4 x 10GE optical ports (SFP+ and LC) |
M7800C-48SFP4XS-EB |
48 x GE optical ports (SFP and LC) + 4 x 10GE optical ports (SFP+ and LC) |
M7800C-36GT12SFP4XS-EB |
36 x GE electrical ports (RJ45) + 12 x GE optical ports (SFP and LC) + 4 × 10GE optical ports (SFP+ and LC) |
*M7800C-24QXS-DA |
24-port 40G Ethernet optical interface board (OSFP+ and MPO) |
*RG-WALL 1600-B-F |
High-performance firewall module |
*RG-M7800C-WS-F |
Wireless control module |
Note: The item marked with the asterisk (*) will be available in the future.
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Contáctenos
How can we help you?