Compare Products
Hide
VS
Business systems such as medical care, libraries, exhibition centers, websites and other gigabit access.
Modelos
Serie
Características destacadas
Hardware Specifications |
RG-CS83-12GT4XS-P |
RG-CS83-24GT4XS |
RG-CS83-48GT4XS |
RG-CS83-24GT4XS-P |
RG-CS83-48GT4XS-P |
Interface Specifications |
|||||
Fixed ports |
12 x 100M/1000M BASE-T ports 4 x 1GE/10GE SFP+ ports support PoE+ |
24 x 100M/1000M BASE-T ports 4 x 1GE/10GE SFP+ ports |
48 x 100M/1000M BASE-T ports 4 x 1GE/10GE SFP+ ports |
24 x 100M/1000M BASE-T ports 4 x 1GE/10GE SFP+ ports support PoE+ |
48 x 100M/1000M BASE-T ports 4 x 1GE/10GE SFP+ ports support PoE+ |
Fan module |
1 x fixed fan module |
No fan |
1 x fixed fan module |
1 x fixed fan module |
1 x fixed fan module |
Power module |
1 x fixed power module |
1 x fixed power module |
1 x fixed power module |
1 x fixed power module |
1 x fixed power module |
Fixed management port |
1 x console, and 1 x USB 2.0 port |
||||
System Specifications |
|||||
Packet forwarding rate |
78 Mpps |
96 Mpps |
132 Mpps |
96 Mpps |
132 Mpps |
Switching capacity |
104 Gbps |
128 Gbps |
176 Gbps |
128 Gbps |
176 Gbps |
MAC address table size |
16,000 |
||||
ARP table size |
4,000 |
4,000 |
4,000 |
4,000 |
4,000 |
Number of IPv4 unicast routes |
6,000 |
||||
Number of IPv4 multicast routes |
1,000 |
||||
Number of IPv6 unicast routes |
2,000 |
||||
Number of IPv6 multicast routes |
750 |
||||
Number of ACEs |
Ingress: 1,750 Egress: 800 |
||||
Number of VSU members |
4 |
4 |
4 |
4 |
4 |
Dimensions and Weight |
|||||
Dimensions (W x D x H) |
442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) |
442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) |
442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) |
442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) |
442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) |
Weight |
3 kg (6.61 lbs) |
3 kg (6.61 lbs) |
3 kg (6.61 lbs) |
3 kg (6.61 lbs) |
3.75 kg (8.27 lbs) |
CPU and Storage |
|||||
CPU |
1.0 GHz dual-core CPU |
1.0 GHz dual-core CPU |
1.0 GHz dual-core CPU |
1.0 GHz dual-core CPU |
1.0 GHz dual-core CPU |
Flash memory |
512 MB |
512 MB |
512 MB |
512 MB |
512 MB |
BootROM |
16 MB |
16 MB |
16 MB |
16 MB |
16 MB |
SDRAM |
1 GB |
1 GB |
1 GB |
1 GB |
1 GB |
Data packet buffer |
4 MB |
4 MB |
4 MB |
4 MB |
4 MB |
Power and Consumption |
|||||
Maximum power consumption |
< 35 W (non-PoE) < 405 W (PoE full load) |
< 25 W |
< 40 W |
< 35 W (non-PoE) < 405 W (PoE full load) |
< 52 W (non-PoE) < 460 W (PoE full load) |
Maximum output power |
409 W Maximum PoE output :370W |
25 W |
40 W |
409 W Maximum PoE output :370W |
460 W Maximum PoE output :405W |
Rated input voltage |
100 V AC to 240 V AC |
100 V AC to 240 V AC |
100 V AC to 240 V AC |
100 V AC to 240 V AC |
100 V AC to 240 V AC |
Maximum input voltage |
90 V AC to 264 V AC, 50 Hz to 60 Hz |
90 V AC to 264 V AC, 50 Hz to 60 Hz |
90 V AC to 264 V AC, 50 Hz to 60 Hz |
90 V AC to 264 V AC, 50 Hz to 60 Hz |
90 V AC to 264 V AC, 50 Hz to 60 Hz |
Environment and Reliability |
|||||
MTBF |
24.14 years |
23.74 years |
23.85 years |
23.94 years |
22.86 years |
Primary airflow |
Front-to-right and left-to-right airflow |
||||
Operating temperature |
0°C to 45°C (32°F to 113°F) |
||||
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
||||
Operating humidity |
10% to 90% RH (non-condensing) |
||||
Storage humidity |
5% to 95% RH (non-condensing) |
||||
Operating noise |
27℃: < 35 dB |
< 20 dB |
27℃: < 32 dB |
27℃: < 35 dB |
27℃: < 35 dB |
Interface surge protection |
Power port: 6 kV(common mode)/8 kV (differential mode) Communication port: 10 kV |
Power port: 6 kV(common mode)/6 kV (differential mode) Communication port: 10 kV |
Power port: 6 kV(common mode)/6 kV (differential mode) Communication port: 10 kV |
Power port: 6 kV(common mode)/8 kV (differential mode) Communication port: 10 kV |
Power port: 6 kV(common mode)/8 kV (differential mode) Communication port: 10 kV |
RG-CS83 Series |
|
Feature |
Description |
Ethernet switching |
Jumbo frame (maximum length: 9,216 bytes) |
IEEE 802.1Q (4K VLANs) |
|
Voice VLAN |
|
Super-VLAN and private VLAN |
|
MAC address-based VLAN, interface-based VLAN, protocol-based VLAN, and IP subnet-based VLAN |
|
GVRP |
|
Basic QinQ Selective QinQ |
|
STP, RSTP, and MSTP |
|
ERPS (G.8032) |
|
LLDP/LLDP-MED |
|
IP service |
ARP |
DHCP client, DHCP relay, and DHCP server |
|
DHCP snooping |
|
DNS |
|
DHCPv6 client, DHCPv6 relay, and DHCPv6 server |
|
DHCPv6 snooping |
|
Neighbor Discovery (ND) and ND snooping |
|
IP routing |
Static routing |
RIP and RIPng |
|
OSPFv2 and OSPFv3 |
|
IPv4 and IPv6 VRF |
|
IPv4 and IPv6 PBR |
|
Multicast |
IGMP v1/v2/v3, and IGMP proxy |
IGMP v1/v2 snooping |
|
PIM-DM, PIM-SM, and PIM-SSM |
|
MSDP |
|
MLD v1/v2 |
|
MLD snooping v1/v2 |
|
PIM-SMv6 and PIM-SSM v6 |
|
ACL and QoS |
Standard IP ACLs Extended IP ACLs Extended MAC ACLs Time-based ACLs Expert-level ACLs ACL80 IPv6 ACL |
ACL redirection |
|
Traffic rate limiting on an interface |
|
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ |
|
Congestion avoidance: tail drop |
|
802.1p/DSCP/ToS traffic classification Eight priority queues per interface |
|
Security |
Multiple AAA modes |
RADIUS and TACAS+ |
|
Interface-based and MAC address-based 802.1x authentication |
|
Web authentication |
|
HTTPS |
|
SSHv1 and SSHv2 |
|
Global IP-MAC binding |
|
Port isolation and port security |
|
IP source guard |
|
SAVI |
|
CPP and NFPP |
|
Reliability |
REUP, RLDP, DLDP |
IPv4 VRRP v2/v3 and IPv6 VRRP |
|
BFD |
|
Link tracing, fault notification, and remote loopback based on 802.3ah (EFM) |
|
Hot swapping of power modules and cables |
|
Fan speed adjustment Fan fault alarm |
|
Device virtualization |
Virtual Switching Unit (VSU) |
NMS and maintenance |
SPAN, RSPAN |
sFlow |
|
NTP and SNTP |
|
FTP and TFTP |
|
SNMP v1/v2/v3 |
|
RMON (1, 2, 3, 9) |
|
NETCONF |
|
CWMP (TR-069) |
|
gRPC |
|
Cloud and SON |
|
PoE |
RG-CS83-12GT4XS-P, RG-CS83-24GT4XS-P, and RG-CS83-48GT4XS-P: IEEE 802.3af and 802.3at Warm start Interface priority |
Order switches, expansion modules, power supply modules, and other components as needed. Before ordering an expansion module or power supply module, please contact our online customer service team for the latest support information about the module.
Model |
Description |
RG-CS83-12GT4XS-P |
12 x 10M/100M/1000M electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, PoE power supply, a maximum of 370 W PoE output, and built-in power module |
RG-CS83-24GT4XS |
24 x 10M/100M/1000M electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, and built-in power module |
RG-CS83-48GT4XS |
48 x 10M/100M/1000M electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, and built-in power module |
RG-CS83-24GT4XS-P |
24 x 10M/100M/1000M electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, PoE power supply, a maximum of 370 W PoE output, and built-in power module |
RG-CS83-48GT4XS-P |
48 x 10M/100M/1000M electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, PoE power supply, a maximum of 405 W PoE output, and built-in power module |
Mini-GBIC-GT |
1000BASE-GT mini GBIC module |
MINI-GBIC-SX-MM850 |
Single-port 1000BASE-SX mini GBIC module (LC connector) |
MINI-GBIC-LX-SM1310 |
Single-port 1000BASE-LX mini GBIC module (LC connector) |
MINI-GBIC-LH40-SM1310 |
Single-port 1000BASE-LH mini GBIC module (LC connector), supporting a transmission distance of 40 km (24.85 miles) |
MINI-GBIC-ZX50-SM1550 |
Single-port 1000BASE-ZX mini GBIC module (LC connector), supporting a transmission distance of 50 km (24.85 miles) |
MINI-GBIC-ZX80-SM1550 |
Single-port 1000BASE-ZX mini GBIC module (LC connector), supporting a transmission distance of 80 km (24.85 miles) |
MINI-GBIC-ZX100-SM1550 |
1000BASE-ZX mini GBIC module, supporting a transmission distance of 100 km (62.14 miles) |
XG-SFP-SR-MM850 |
10GE LC module (62.5/125 μm: 33 m (108.27 ft.); 50/125 μm: 66 m (216.54 ft.); transmit for 300 m (984.25 ft.) when modal bandwidth is 2000 MHz * km), applicable to SFP+ ports |
XG-SFP-LR-SM1310 |
10GE LC interface module (1310 nm), 10 km (6.21 miles), applicable to SFP+ ports |
XG-SFP-ER-SM1550 |
10GE LC interface module (1550 nm), 40 km (24.85 miles), applicable to SFP+ ports |
XG-SFP-AOC1M |
10GE SFP+ fiber-optic cable, 1 m (3.28 ft.), including one cable and two interface modules |
XG-SFP-AOC3M |
10GE SFP+ fiber-optic cable, 3 m (3.28 ft.), including one cable and two interface modules |
XG-SFP-AOC5M |
10GE SFP+ fiber-optic cable, 5 m (3.28 ft.), including one cable and two interface modules |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Contáctenos
How can we help you?
Your opinions and feelings are crucial for our improvement.
Fill in the survey